Problem
The possible reasons
Solution Short running after fracture triangular belts,torn apart Installed too close, tension is too large to cause line damageNo tension according to the instructions for installation, ensure the correct tension A foreign body in the process of operation.
Check whether the install shield, if not installed, needs to be installed The transmission system stuck.
Check device wiring and trouble shooting Transmission system design index is low, v-belt quantity is not enough Check the system, to determine the related indicators The unreasonable installation, direct device prizing, damage the skeleton material Follow the instructions to make reasonable installation requirements Mix of old and new V beltReplace with a new set of V belt Common V belt and toughened V belt mixed use.
Use the same kind of V belt V belt edge of excessive wear.
The tension is too low.
Check and adjust the tension V belt is too wide or too narrow.
Check the V belt and pulley compatibility or replace pulley Starting torque is too wide.
Check the transmission case, restart Pulley groove wear.
Replace the pulley The pulley is not alignedCheck and align pulley.
Pulley Angle is wrong.
Processing or replace the pulley V-belt contact with other objects.
Remove the object and do the corresponding clean protection V belt bottom has excessive use Replace the hexagonal belts.https://www.triangularbelt.com